»  HOME  
Part of the Super Stud Building Products Family of Companies
SuperStud Energex DragonBoard Galaxy
INSTALLATION


Preparatory Work
Methods
Precautions
Building Codes

   Preparatory Work:

Accept and install only DragonBoard® supplied by an authorized DragonBoard® dealer, in manufacturer’s original, unopened, undamaged containers with identification labels intact. Only material purchased from an authorized DragonBoard dealer or distributor will be warranted by the manufacturer. (Contact DRAGONBOARD USA customer service to verify authorized-dealer status)


   Methods:

DRAGONBOARD® can be cut, trimmed or shaped using ordinary power tools.
DRAGONBOARD® panels may be fastened to supporting joists or studs using self-drilling, self-countersinking, corrosion-protected, #10 cement board screws. (Contact DRAGONBOARD® technical services for detailed fastener recommendations)

The smooth side of DRAGONBOARD® is suitable for painting with no further preparation. Textured side is suitable for application of ceramic tile. Use either solvent-based oil paint or water-based latex paint.

DRAGONBOARD® is not recommended for prolonged direct exposure to rain or weather. DRAGONBOARD® panels indirectly exposed to the elements, require an application of a prime coat of acrylic-siloxane waterproofing sealant, followed by oil-based paint.

Where DRAGONBOARD® is to be used as a mounting substrate for ceramic tile, as in a bath or shower enclosure, solvent-based tile mastic is recommended.

DRAGONBOARD® recommended assemblies consist of interior wall, staircase, ceiling and floor/ceiling assemblies. (For all other applications contact DRAGONBOARD® technical services.)

UL rated fire assemblies can be viewed on www.UL.com under Certifications, key-word DRAGONBOARD® or on the DRAGONBOARD® website, www.dragonboard.com .

*WHEN INSTALLING DRAGONBOARD® FLOORING, ALWAYS INSTALL SMOOTH SIDE UP. When floor joists are installed on greater than 16” centers, contact DRAGONBOARD® technical services for installation guidance. There are many floor design options that can be utilized with DragonBoard® to deliver varying degrees of sound and stiffness performance. Please contact DragonBoard® technical services for assistance with these design options.


  Precautions:

• Use caution when handling wet DRAGONBOARD® panels.

• DRAGONBOARD® contains no carcinogenic material. However, a dust mask is always recommended during routing, cutting and/or sanding operations.

• The use of gloves is suggested to avoid abrasion injuries.

• Fasteners should be no closer than 2” (50mm) from corners, with the adjoining screw not less than 4”(100 mm) from the same corner.

• Do not install screws at 45° angles on corners.

• Always support board ends by joists.

• Always install any fasteners over supporting structures.

• Fasteners should be no closer than ¾” (19mm) from any edge.

• DRAGONBOARD® is not recommended for overhanging cantilevers.

• Do not install mechanical fasteners (nails, screws, staples, etc) directly to DRAGONBOARD®

• The use of “setting” compounds and mesh tape for seams is recommended.


  Building Codes:

Installation must comply with all applicable local, state and federal codes.
HOME  |  PRODUCT LITERATURE  |  CAREERS  |  SITE MAP  |  CONTACT US